3-Phase Flexible Current Probe with 3VDC Full-Scale Output available in 24, 36 and 48 inch probe cable lengths.
Electrical Characteristics
| Current Ranges | 60A / 600A / 6000A AC RMS (selectable via rotary switch) | 
| Output Sensitivity | 50mV / 5mV / 0.5mV per A (AC coupled) | 
| Accuracy (at 25°C) | ± 1% of reading ± 0.1A (60A range) ± 1% of reading ± 1A (600A / 6000A range) | 
Physical Characteristics
| Probe and Cable Material | Alcryn 2070 NC LATENE 7H2W V0 | 
| Probe Cable Length | 610mm (24”) / 915mm (36”) / 1220mm (48”) | 
| Probe Cable Diameter | 9.9mm (nominal) | 
| Cable Length | 2m (Probe to Integrator box) | 
| Output | 0.5m long lead terminated with 3 X safety male BNC | 
3-Phase Flexible Current Probe with 3VDC Full-Scale Output  available in 24, 36 and 48 inch probe cable lengths
Electrical Characteristics
| Current Ranges | 30A / 300A / 3000A AC RMS (selectable via rotary switch) | 
| Output Sensitivity | 100mV / 10mV / 1mV per A (AC coupled) | 
| Accuracy (at 25°C) | ± 1% of reading ± 0.1A (30A range) ± 1% of reading ± 1A (300A / 3000A range) | 
Physical Characteristics
| Probe and Cable Material | Alcryn 2070 NC LATENE 7H2W V0 | 
| Probe Cable Length | 610mm (24”) / 915mm (36”) / 1220mm (48”) | 
| Probe Cable Diameter | 9.9mm (nominal) Cable Length 2m (Probe to Integrator box) | 
| Output | 0.5m long lead terminated with 3 X safety male BNC | 

1-Phase Flexible Current Probe [Compatible with Fluke 1750 and RPM Power Recorders] available in 24, 36 and 48 inch probe cable lengths
Electrical Characteristics
| Current Ranges | 100A / 1000A / 5000A AC RMS (selectable via rotary switch) | 
| Output Sensitivity | 20mV / 2mV / 0.4mV per A (AC coupled) | 
| Accuracy | (at 25°C) ± 1% of reading ± 0.1A (100A range) ± 1% of reading ± 1A (100A / 5000A range) | 
Physical Characteristics
| Probe and Cable Material | Alcryn 2070 NC LATENE 7H2W V0 | 
| Probe Cable Length | 610mm (24”) / 915mm (36”) / 1220mm (48”) | 
| Probe Cable Diameter | 9.9mm (nominal) | 
| Cable Length | 2m (Probe to Integrator box) | 
| Output | 0.5m long lead terminated with a 6-pin male LEMO | 
Single Phase Flexible AC Current Probe with 3 VDC Full-Scale Output available in 24, 36 and 48 inch probe cable lengths
Electrical Characteristics
| Current Ranges | 60A / 600A / 6000A AC RMS (selectable via rotary switch) | 
| Output Sensitivity | 50mV / 5mV / 0.5mV per A (AC coupled) | 
| Accuracy | (at 25°C) ± 1% of reading ± 0.1A (60A range) ± 1% of reading ± 1A (600A / 6000A range) | 
Physical Characteristics
| Probe and Cable Material | Alcryn 2070 NC LATENE 7H2W V0 | 
| Probe Cable Length | 610mm (24”) / 915mm (36”) / 1220mm (48”) | 
| Probe Cable Diameter | 9.9mm (nominal) Cable Length 2m (Probe to Integrator box) | 
| Output | 0.5m long lead terminated with a safety male BNC | 
3-Phase 24" Flexible Current Probe with 3VDC Full-Scale Output. 
24" circumference. 
New design with 3 ranges: 600 A / 1200 A / 3000 A.
New power supply - battery or instrument power.
Electrical Characteristics
| Current Ranges | 600A / 1200A / 3000A AC RMS | 
| Output Sensitivity | 5mV / 2.5mV / 1 mV / A [x200/x400/x1000] | 
| Accuracy (at 25°C) | ±1% of reading ± 1A | 
Physical Characteristics
| Probe and Cable Material | Alcryn 2070 NC LATENE 7H2W V0 | 
| Probe Cable Length | 610mm (24”) / 915mm (36”) / 1220mm (48”) | 
| Probe Cable Diameter | 9.9mm (nominal) | Cable Length 2m (Probe to Integrator box) | 
| Output | 0.5m long lead terminated with 3 X safety male BNC | 
Single Phase Flexible AC Current Probe with 3 VDC Full-Scale Output available in 24, 36 and 48 inch probe cable lengths
Electrical Characteristics
| Current Ranges | 30A / 300A / 3000A AC RMS (selectable via rotary switch) | 
| Output Sensitivity | 100mV / 10mV / 1mV per A (AC coupled) | 
| Accuracy | (at 25°C) ± 1% of reading ± 0.1A (30A range) ± 1% of reading ± 1A (300A / 3000A range) | 
General Characteristics
| Probe and Cable Material | Alcryn 2070 NC LATENE 7H2W V0 | 
| Probe Cable Length | 610mm (24”) / 915mm (36”) / 1220mm (48”) | 
| Probe Cable Diameter | 9.9mm (nominal) | 
| Cable Length | 2m (Probe to Integrator box) | 
| Output | 0.5m long lead terminated with a safety male BNC | 
            