Product and page has been discontinued. See below list of our current products
Power Quality and Energy Instruments Available from POWERetc
POWERetc offers an extensive line of instruments from the most popular manufacturers including Fluke, Dranetz, Power Standards Lab and PROSyS.
If you are familiar with a particular product and you’re sure it can handle the task you have at hand, then just scroll down this list and select the product you want.
If, on the other hand, you are not sure what you need or want to explore alternatives, then we suggest you go to our selection guide where we will walk you through a series of basic questions to help you arrive at the right tool for your task.
Purchase
3-Phase Flexible Current Probe with 3VDC Full-Scale Output available in 24, 36 and 48 inch probe cable lengths
Electrical Characteristics
Current Ranges |
30A / 300A / 3000A AC RMS (selectable via rotary switch) |
Output Sensitivity |
100mV / 10mV / 1mV per A (AC coupled) |
Accuracy (at 25°C) |
± 1% of reading ± 0.1A (30A range) ± 1% of reading ± 1A (300A / 3000A range) |
Physical Characteristics
Probe and Cable Material |
Alcryn 2070 NC LATENE 7H2W V0 |
Probe Cable Length |
610mm (24”) / 915mm (36”) / 1220mm (48”) |
Probe Cable Diameter |
9.9mm (nominal) Cable Length 2m (Probe to Integrator box) |
Output |
0.5m long lead terminated with 3 X safety male BNC |
Compatible Instruments
Can be connected to most measuring Dranetz Power instruments including multimeters, oscilloscopes PQ recording devices. [Note: most of these devices have 4mm banana jack inputs and would require a standard BNC-to-Double Banana adapter.]
Purchase
1-Phase Flexible Current Probe [Compatible with Fluke 1750 and RPM Power Recorders] available in 24, 36 and 48 inch probe cable lengths
Electrical Characteristics
Current Ranges |
100A / 1000A / 5000A AC RMS (selectable via rotary switch) |
Output Sensitivity |
20mV / 2mV / 0.4mV per A (AC coupled) |
Accuracy |
(at 25°C) ± 1% of reading ± 0.1A (100A range) ± 1% of reading ± 1A (100A / 5000A range) |
Physical Characteristics
Probe and Cable Material |
Alcryn 2070 NC LATENE 7H2W V0 |
Probe Cable Length |
610mm (24”) / 915mm (36”) / 1220mm (48”) |
Probe Cable Diameter |
9.9mm (nominal) |
Cable Length |
2m (Probe to Integrator box) |
Output |
0.5m long lead terminated with a 6-pin male LEMO |
Purchase
Single Phase Flexible AC Current Probe with 3 VDC Full-Scale Output available in 24, 36 and 48 inch probe cable lengths
Electrical Characteristics
Current Ranges |
60A / 600A / 6000A AC RMS (selectable via rotary switch) |
Output Sensitivity |
50mV / 5mV / 0.5mV per A (AC coupled) |
Accuracy |
(at 25°C) ± 1% of reading ± 0.1A (60A range) ± 1% of reading ± 1A (600A / 6000A range) |
Physical Characteristics
Probe and Cable Material |
Alcryn 2070 NC LATENE 7H2W V0 |
Probe Cable Length |
610mm (24”) / 915mm (36”) / 1220mm (48”) |
Probe Cable Diameter |
9.9mm (nominal) Cable Length 2m (Probe to Integrator box) |
Output |
0.5m long lead terminated with a safety male BNC |
Compatible Instruments
Can be connected to most measuring Dranetz Power instruments including multimeters, oscilloscopes PQ recording devices. [Note: most of these devices have 4mm banana jack inputs and would require a standard BNC-to-Double Banana adapter.]
Purchase
3-Phase 24" Flexible Current Probe with 3VDC Full-Scale Output.
24" circumference.
New design with 3 ranges: 600 A / 1200 A / 3000 A.
New power supply - battery or instrument power.
Electrical Characteristics
Current Ranges |
600A / 1200A / 3000A AC RMS |
Output Sensitivity |
5mV / 2.5mV / 1 mV / A [x200/x400/x1000] |
Accuracy (at 25°C) |
±1% of reading ± 1A |
Physical Characteristics
Probe and Cable Material |
Alcryn 2070 NC LATENE 7H2W V0 |
Probe Cable Length |
610mm (24”) / 915mm (36”) / 1220mm (48”) |
Probe Cable Diameter |
9.9mm (nominal) | Cable Length 2m (Probe to Integrator box) |
Output |
0.5m long lead terminated with 3 X safety male BNC |
Compatible Instruments
Can be connected to most measuring Dranetz Power instruments including multimeters, oscilloscopes PQ recording devices. [Note: most of these devices have 4mm banana jack inputs and would require a standard BNC-to-Double Banana adapter.]
Purchase
Single Phase Flexible AC Current Probe with 3 VDC Full-Scale Output available in 24, 36 and 48 inch probe cable lengths
Electrical Characteristics
Current Ranges |
30A / 300A / 3000A AC RMS (selectable via rotary switch) |
Output Sensitivity |
100mV / 10mV / 1mV per A (AC coupled) |
Accuracy |
(at 25°C) ± 1% of reading ± 0.1A (30A range) ± 1% of reading ± 1A (300A / 3000A range) |
General Characteristics
Probe and Cable Material |
Alcryn 2070 NC LATENE 7H2W V0 |
Probe Cable Length |
610mm (24”) / 915mm (36”) / 1220mm (48”) |
Probe Cable Diameter |
9.9mm (nominal) |
Cable Length |
2m (Probe to Integrator box) |
Output |
0.5m long lead terminated with a safety male BNC |
Compatible Instruments
Can be connected to most measuring Dranetz Power instruments including multimeters, oscilloscopes PQ recording devices. [Note: most of these devices have 4mm banana jack inputs and would require a standard BNC-to-Double Banana adapter.]
Purchase
Single Phase AC Current Probe
The new Micro-flex ACP 3003_16 is a single-phase AC current clamp utilizing the Rogowski principle. It can be used to measure currents up to 3000A from very low frequencies to 10kHz. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and with large conductors.
Electrical Characteristics
Current Ranges |
600 A/1200 A/3000A AC RMS (selectable via rotary switch) |
Output Sensitivity |
5mV/2.5mV/1.0mV/A [x200/x400/x1000] |
Accuracy (at 25°C) |
±1% of reading ± 1A |
Physical Characteristics
Probe and Cable Material |
Alcryn 2070 NC, Arnite TO6-200SNF |
Probe Cable Length |
70mm (3”) / 100mm (4”) |
Probe Cable Diameter |
6mm (nominal) |
Cable Length |
2m (Probe to Integrator box) |
Output |
0.5m long lead terminated with a safety male BNC |
Compatible Instruments
Can be connected to most measuring Dranetz Power instruments including multimeters, oscilloscopes PQ recording devices. [Note: most of these devices have 4mm banana jack inputs and would require a standard BNC-to-Double Banana adapter.]
Purchase
Three Phase AC Current Probe
The new Micro-flex ACP 3003_16 is a 3-Phase AC current clamp utilizing the Rogowski principle. It can be used to measure currents up to 3000A from very low frequencies to 10kHz. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and with large conductors.
Electrical Characteristics
Current Ranges |
600 A/1200 A/3000A AC RMS (selectable via rotary switch) |
Output Sensitivity |
5mV/2.5mV/1.0mV/A [x200/x400/x1000] |
Accuracy (at 25°C) |
±1% of reading ± 1A |
Physical Characteristics
Probe and Cable Material |
Alcryn 2070 NC, Arnite TO6-200SNF |
Probe Cable Length |
70mm (3”) / 100mm (4”) |
Probe Cable Diameter |
6mm (nominal) |
Cable Length |
2m (Probe to Integrator box) |
Output |
0.5m long lead terminated with a safety male BNC |
Compatible Instruments
Can be connected to most measuring Dranetz Power instruments including multimeters, oscilloscopes PQ recording devices. [Note: most of these devices have 4mm banana jack inputs and would require a standard BNC-to-Double Banana adapter.]